Plastic Copper – Aluminium Wire

PVC insulated cable (wire) with rated voltage up to and including 450/750V

  • Standards
  • The cable is manufactured to IEC227-2007, It is suitable to be used for illumination of power devices with AC at rated voltage up to and including 450/750V.
  • Type and Name
Model Description

Rated voltage V

Nominal cross Section

British
standard
wire 

 BV 
BLV 
 Copper or Aluminium core PVC insulation power line cable(wire)   300/500  0.5-1.0

3029,
3036,
7029,
7036,
7044,
7052,
7064,

       7083       

 450/750  1.5-400
 BVV
BLVV
 Copper or Aluminium core PVC insulation PVC sheath round
power line cable(wire)
 300/500  0.75-35
 BVR  Copper core PVC insulation flexible power line cable (wire)        450/750   2.5-70
 BVVB
BLVVB
 Copper or Aluminium core PVC insulation PVC sheath power
line cable(wire)
 300/500     0.75-10
  BV90℃   Copper core heat-resistance PVC insulation cable(wire) 90℃  300/500  0.5-1.0
 450/750     1.5-400
  RV   Copper core PVC insulation jointed flexible cable (wire)  300/500  0.5-1.0
 450/750  1.5-240
 RVB  Copper core PVC insulation paralled flexible cable (wire)  300/300  0.5-0.75
 RVS  Copper core PVC insulation twisted joint flexible cable (wire)  300/300  0.5-0.75
 RVV  Copper core PVC insulation sheath parallel joint flexible cable
(wire)
 300/500     0.5-2.5
  RVVB   Copper core PVC insulation sheath parallel joint flexible
cable(wire)
 300/500  0.5-0.75
 450/750  0.75
  RV90   Copper core heat-resistance lose PVC joint flexible cable(wire)
90
 300/500  0.5-1.0
 450/750  1.5-240   

 

Note:

we can produce not only the above cable, but also flame-retardant cable, fire resistance cable and low smoke, low halogen, flame-retardant cable. You can only plus ZR (A), ZR (B), ZR (C) or NH (A), NH (B) beforethe type of common cable (wire)

Application

    It applies to electrical appliance, instrument and telecom device with rated voltage up to and including 450/750 volts.

    The main features of the flame retardant PVC cable or wire is hard to get fire or that the continuous burning of cables is very limited when it ison fire. It applies to the places with special demands for flame retardant property. Flame retardant cable is classified as class A, B or C. Among the 3 class, class A is the best, while C worst.

    The main features of the flame retardant PVC cable or wire is hard to get fire or that the continuous burning of cables is very limited when it ison fire. It applies to the places with special demands for flame retardant property. Flame retardant cable is classified as class A, B or C. Among the 3 class, class A is the best, while C worst.

Standards

    IEC 227 – 2007 British Standard wire.

    The Main Feature of Cable (wire)

     Rated voltage U0 /U is 450/750 volt, 300/500 volt or 300/300 volt.


    Permissible continuous working temperature of cable conductor for type of cable RV-105 and BV-105, the temperature should be less than 90℃, for others, the temperature should be less than 70℃.

    Ambient temperature should be not less than 0℃ and permissible bending radius of cable for fixed connecting should be as follows during installation – for O.D. less than 25 millimeter, equal or greater than 4 times O.D., for O.D. not less than 25 millimeter, equal to or greater than 6 times O.D.
    Flame retardant cable should pass the test of bunched cables or wires under fire conditions which is described in the standards of IEC 332-3. Fire resistance cable should pass the test of fire Resistance stipulated in the standards of IEC.